Place hydrants and static water sources, keep the hydrants you reuse in a library, add published hydrants nearby, and see what checks Water Supply.
Loading…
What this does not do
a published location is the utility's record, not a flow test or proof of water — confirm water supply on scene. Coverage is only the City of Rochester's and the Monroe County Water Authority's service areas in Monroe County, NY, and the Charlotte County Utilities hydrants within about 3 miles of one fire station in Port Charlotte, FL, not the rest of Charlotte County; an empty list means no published data covers the location, never that there is no water. MCWA publishes no service status, so every MCWA hydrant reads "status not published". The list is a copy CTT imports from each publisher, not a live feed. Training, pre-planning, and after-action review only — never live-incident reliance.
training, pre-planning, and after-action review only — never live-incident reliance. Not a CAD or dispatch system; nothing here dispatches or tracks a unit in real time. Apparatus draw at typical dimensions for their type, not a unit's own measurements. An aerial's scrub circle is estimated from that drawing until the department enters the unit's own figure, and the estimate can run several feet short for a tower or platform. The circle shows room to swing only: it does not check overhead wires, trees, or the ground under the jacks. An aerial's reach ring and drag stop are a typical 100-foot aerial scaled to the length on the unit's aerial equipment: an estimate, not the device's published reach, and an aerial with no length recorded reaches as a 100-foot aerial.
The Hydrants panel in the left sidebar holds three things: the hydrants and static water sources on this incident, your department's hydrant library, and the hydrants a water utility has published near the incident.
Place a hydrant
The choice at the top of the panel, Hydrant or Static source, decides what the next placement is. Screen readers announce it as What to place. Hydrant is the default.
+ Place Hydrant turns on the hydrant tool. Click the map where the hydrant is.
Add at Map Center drops a hydrant at the center of the map view. Drag any placed hydrant on the map to move it.
Click a hydrant's name in the list to rename it. Save to Library keeps a copy, with its main size, in your department's library.
Set main size under a hydrant's name records the size of the water main feeding it, in inches, from 1 to 48. The list then reads, for example, 8" main. Click the size to change it, or clear it to remove it.
Add notes under a hydrant or a static source opens a box for notes the next crew should know, up to 500 characters. Click away to save them, or press Escape to leave them as they were. Edit notes changes them, and emptying the box removes them. A hydrant you save to the library keeps its notes, and you can add or change notes on a library hydrant the same way.
Library switches the list to that library, Load places a saved hydrant on this incident, and Placed switches back.
OOS on a hydrant's row marks it out of service on this incident. The row reads Out of service, and every view shows the mark: the map draws the hydrant as a black circle with a small warning triangle instead of the red one, and Street View and the 3D view draw its marker black with the same triangle. Press OOS again to put it back in service. The mark stays with this incident: Save to Library doesn't copy it, and an out-of-service hydrant doesn't count toward Water Supply (see below). A replay shows the hydrant out of service from the moment you marked it.
Adding, moving, removing, and marking a hydrant out of service can be undone like any other change on the board. See Undo, redo, and saving.
Place a static water source
A static source is water an engine drafts from where there is no hydrant: a pond, a pool, a cistern, a river, or, on a rural fireground, a portable tank (a drafting pool) that a tanker shuttle keeps filled.
Choose Static source at the top of the panel.
Under What is it?, choose what the water is: Pond, Lake, Pool, Cistern, Dry hydrant, Portable tank, River or stream, or Other. Nothing is placed until you choose. The place buttons stay unavailable, and a click on the map or in Street View only reminds you to choose first.
Press + Place Static Source and click the map where the water is, or press Add at Map Center.
On the map, a static source is a blue circle with two white waves instead of the red H, so it never reads as a hydrant. Point at it to see its name and what it is, for example "Pond (static water source)". In Street View it is a blue chip with the same two waves, and in the 3D views it is the same blue circle with two white waves.
In the list, a static source's second line says what it is; change it there if you chose the wrong type. Rename, move, and remove a static source the same way as a hydrant, and undo any of those the same way too.
It stays on the incident. A static source has no Save to Library button, because the library holds hydrants only.
It has no main size. Its second line is its type instead.
Its kind is fixed. A placed hydrant can't become a static source, or the reverse. Remove it and place the other kind.
Draft with hard suction
An engine or quint drafts from a static source through its hard suction. Parking beside the water isn't enough, and a tanker doesn't draft. An engine you add in the app starts with 20 feet of 6-inch hard suction. A truck, quint, tiller, or tiller quint starts with none, because most don't carry it. To give a quint, or an engine without it, hard suction, add an item of type Hard suction to it; see Program your hose loads.
Select the engine on the map and press Deploy Equipment. The button appears once the engine's position is saved.
Press Deploy beside the hard suction.
Draw the line from the engine to the static source and let go on the source. The end of a hard suction snaps onto the nearest hydrant or static source within 25 feet of where you let go. It never snaps onto an apparatus, not even the engine it came from, so let go near the water.
On the map, every hard suction line has a white outline and a gray spiral along its length, whatever its color, so you can tell it from any other line. New hard suction is black. Zoomed far out, the spiral drops and the outline carries the line. Street View draws the spiral as gray bands across the line, and the 3D view draws the outline alone.
Hard suction is laid once, like a preconnect. Drawing more than its length warns you the same way any hose load does, and you keep drawing.
What checks Water Supply and Secondary Water
On the Tactics tab in the right sidebar, Water Supply and Secondary Water check themselves when the board shows water reaching an engine. The line under Water Supply sums it up: "Checks when a 3-inch or larger line feeds an engine from a hydrant or draft."
A chain starts at a source and reaches an engine or quint through lines of 3 inches or more. The source is a hydrant that isn't marked out of service, or a static source that an engine or quint drafts from through its hard suction. A chain can pass through relays from one apparatus to another, including a tanker that pumps into an engine, but it ends only at an engine or quint.
Water Supply checks when there is at least one chain. The engine the water reaches doesn't need a line assigned Primary Attack.
Secondary Water checks when there are two independent chains. They share no source and no pumping apparatus, though both can end at the same engine. Two lines laid along the same chain count as one, and so do two engines on the same source.
These connect a chain:
A line's end at a hydrant. A line of 3 inches or more with an end within 15 feet of a hydrant carries its water to the apparatus the line comes from, and to an apparatus at its other end. Each end connects to the one hydrant nearest it. When that hydrant is marked out of service, the end connects to it and carries no water; it doesn't reach past it to another hydrant.
Hard suction at a static source. Hard suction whose far end is within 15 feet of a static source drafts for the engine or quint it came from, from the one source nearest that end, so a pond and its dry hydrant count as one source. The end at the engine never drafts. No other line drafts, and an engine without its hard suction out doesn't draft, however close it is parked.
A line's end at another apparatus. A line of 3 inches or more with an end within 15 feet of the center of another apparatus joins the two.
A relay. A line of 3 inches or more that you finish drawing at another apparatus becomes a relay and joins the two. If that apparatus is later moved away from the line's end, the relay no longer reaches it.
A line takes its size from the hose load it was laid from. A load with a diameter set counts at 3 inches or more. A load with no diameter set counts only when it's LDH. Hard suction counts at any size. A line laid before September 26, 2026 has no size on record, so it counts as 3 inches or more.
Only an engine or a quint ends a chain or drafts, and a tiller quint counts as a quint. A brush truck, a wildland engine, and a crash truck carry water and hose, but they don't end a chain or draft. The app records an apparatus's type when you place it on the map, so replay knows it too. An apparatus placed before September 26, 2026 has no type on record, and on those incidents any apparatus can end a chain.
Only a line's ends connect: a line that passes a hydrant or an engine on its way does not. A relay with no source behind it counts for nothing. A line assigned Primary Attack, Backup Line, Exposure Protection, or Search Line is never a supply line, wherever its ends are. A line with no assignment still counts once it is hooked up and large enough, because crews don't always label the line. Hard suction is never an attack line: given Primary Attack or Backup Line, it checks neither Suppression nor Backup Line, and it doesn't draft.
The direction a line was drawn in doesn't matter: a reverse lay drawn from the engine to the hydrant counts the same as a forward lay. In edit mode, a box you check or clear by hand keeps your choice. When you reopen an incident, every box you didn't set by hand follows this rule. Replay applies the same rule to the board at each moment, so both boxes check at the point in the replay where the chains are complete.
A few marks refine the rule where you set them, and a board without them counts as described above. A base pumper always ends a chain and a supply pumper never does, which an engine's Function sets. A supply line laid in to another engine runs from its source straight to that engine, without the engine that laid it; an engine that laid in to its own intake stays on its line. A line's Source or Target connects its end to what it names. A line with any of these marks counts only once it's Charged, and in replay only while it's charged. Supply lays and water on describes the marks.
An incident from before September 26, 2026 follows this rule too, when you reopen it or replay it, and three things can change its boxes:
Drafting. No line laid before that date is hard suction, so an engine parked beside a static source, or a line that ends at one, no longer checks Water Supply.
The attack line. The engine the water reaches no longer needs a line assigned Primary Attack, so a supply line hooked to any engine can now check Water Supply.
Two hydrants at one line end. A line end near two hydrants now connects to the nearer one only, so it no longer counts as two sources for Secondary Water.
Lay from one hose bed more than once
A hose bed stays available after its first lay, the way a crew pulls from a bed more than once. An engine carrying 1,050 feet of LDH that laid a 400-foot relay still has 650 feet to lay to the hydrant.
Select the engine on the map and press Deploy Equipment. The button appears once the engine's position is saved.
Press Deploy beside the bed. A bed with a lay out shows what is left and its full length, for example 650' left of 1050'.
Draw the line. After each stroke, if the line needs more hose than is left on the bed, a warning gives both numbers ("This lay needs … ft; … ft is left in the bed.") and you keep drawing. Dragging a point of a line already laid past what's left shows the same warning as a toast.
What counts as a bed. Any LDH, handline, trash line, or hotel pack on the apparatus that isn't set up as a preconnect in the roster.
When a bed is used up. Once less than a whole foot is left, the bed shows in use and has no Deploy button. The Equipment panel in the left sidebar shows the same length and the same mark.
Removing a lay puts its length back on the bed.
Preconnects stay single-use, and so do ladders, aerials, master streams, blitz fires, and hard suction: one deployment puts the item in use.
Extending a line.Extend, on the line's right-click menu or on the menu at its last point, goes straight back into drawing from where the line ends, and warns the same way when the line needs more hose than is left.
To set up each bed's length, diameter, and slot, and to lay a line straight from its slot on the map, see Program your hose loads.
Published hydrants near the incident
Below the list, Published hydrants lists the hydrants a water utility has published within about a quarter mile of the incident, nearest first. The publishers are the City of Rochester and the Monroe County Water Authority (MCWA) in Monroe County, New York, and Charlotte County Utilities (CCU) in Charlotte County, Florida. In Charlotte County, we've loaded only the CCU hydrants within about 3 miles of one fire station in Port Charlotte, not the whole county. Each row gives the distance in feet, the publisher, and only what that publisher states: flow in GPM, static pressure, main and outlet size, and whether the hydrant is listed in or out of service. A hydrant listed out of service is struck through. MCWA does not publish a service status, so every MCWA hydrant reads "status not published". CCU publishes no main size, and where it publishes no street address, the row shows the utility's ID for the hydrant instead.
The same hydrants appear on the map as hollow rings, drawn beneath the hydrants you placed. A ring takes the hydrant's NFPA flow-class color when the publisher gives one, and a dashed ring means the service status is not published. Hover over a ring to see the hydrant's address or ID, its publisher, and what the publisher states about it. Clear Show on map to hide the rings. The setting is not saved; reloading the page shows them again.
To use a published hydrant, press Place on its row or click its ring on the map. Either one places it on the incident as a working hydrant, named from the published address when there is one. The location, the name, and the published main size are copied. The published flow, pressure, and outlet size stay on the published row. When the publisher gives no main size, the placed hydrant has none until you enter one.
A published hydrant can be placed once. While it is on the incident, its row stays in the list with its published facts, and its button reads Placed instead of Place. Clicking its ring doesn't add a second copy either. A hydrant you placed from the list or a ring still counts as placed after you drag it on the map. Remove the placed hydrant to place it again.
A drill with no location has nothing to search from, so the section does not appear.
"No published hydrant data covers this location" describes the data, not the street. It does not mean there is no water there.
Credits. The foot of the section credits each publisher whose hydrants are listed, and no other. For Charlotte County hydrants, it reads "Hydrants: Charlotte County Utilities, via Charlotte County GIS." The City of Rochester's required disclaimer appears whenever its hydrants are listed.